If you have ever spec'd a bifacial module, you have probably run into the same confusion: why does a 2.0mm PV cover glass only come "semi-tempered" (also called heat-strengthened), while the same supplier's 3.2mm glass is "fully tempered"? Is semi-tempered glass weaker? Is it a shortcut the factory took to save cost?
Short answer: no. The temper type on thin PV glass is decided by physics, not by how much the factory wants to spend. Getting this right directly affects module yield, long-term reliability, and whether your panels survive hail, wind, and 25 years of thermal cycling.
Patterned or float glass goes into a furnace near its softening point, then a bank of high-pressure air quenchers blasts both surfaces. The surface cools and contracts faster than the core. When the core later shrinks, it leaves the surface in a state of compressive stress — that is what makes tempered glass strong.
The difference between the two temper types is how hard you quench:
· Fully tempered (FT): aggressive, high-pressure quench, which builds up a much higher surface compressive stress. The glass breaks into small, blunt cuboids (the classic "safety glass" fragment test). High strength, but higher risk of warpage and a small spontaneous breakage rate from nickel-sulfide inclusions.
· Semi-tempered / heat-strengthened (ST): a much milder quench, so the surface compressive stress stays at a moderate level (per ASTM C1048). The glass breaks into larger pieces with visible crack lines rather than shattering into dice. Warpage is far lower, spontaneous breakage is virtually eliminated, and optical flatness is noticeably better.
Here is the part most spec sheets skip: when the sheet gets thinner than about 2.5mm, an aggressive quench cools the entire section almost instantly. The surface and the core equalize too fast, so it becomes much harder to build up the high surface compression that defines fully tempered glass without introducing unacceptable warpage. Worse, uneven cooling across a thin sheet produces bow and warp. On a 2.0mm front sheet laminated to a 2.0mm back sheet in a bifacial module, even a small amount of warp translates into uneven EVA encapsulation, cell-string stress, and long-term microcrack risk.
That is why the industry converged on a clean split:
· 3.2mm single-sheet cover: fully tempered — it needs the highest hail and wind resistance on a single pane.
· 2.5mm: fully tempered is still achievable without unacceptable warp.
· 2.0mm and 1.6mm: semi-tempered is the standard, because flatness and dimensional stability matter more than the extra MPa of surface compression.
· Far lower warpage, so two 2.0mm sheets laminate flat in a double-glass bifacial module.
· Near-zero spontaneous breakage — a critical point on utility-scale arrays where field failures are expensive.
· When it eventually breaks, it cracks into large pieces rather than shattering into small, scattered particles, so the module stays intact enough for a scheduled replacement rather than becoming an immediate safety hazard.
· It still passes the standard steel-ball impact test and IEC 61730 impact requirements when produced on a properly segmented temper line.
|
Nominal thickness |
Recommended temper |
Typical application |
|
1.6mm |
Semi-tempered |
Double-glass (bifacial) modules |
|
2.0mm |
Semi-tempered |
Double-glass (bifacial) modules |
|
2.5mm |
Fully tempered |
Double-glass modules |
|
3.2mm |
Fully tempered |
Single-glass modules |
A quick rule of thumb: if you are building a bifacial double-glass module in 2.0mm or below, "semi-tempered" is not a downgrade — it is the correct engineering choice. The temper type should always be specified together with thickness, iron content (Fe₂O₃ ≤ 0.012% for ultra-clear), and whether you need single- or double-sided AR coating (a practical transmittance target with AR is ≥ 94%).
Xinfuxing Glass manufactures the full PV cover-glass line — 1.6mm / 2.0mm semi-tempered and 2.5mm / 3.2mm fully tempered ultra-clear patterned glass, with optional double-sided AR and anti-soiling coating. If you are specifying glass for a bifacial, floating (FPVS), or extreme-climate project, contact us for current spec sheets and mill test reports.